Metrologics Orbit MS7120 Suffix
The Metrologies Orbit MS7120 serial scanner uses the OPOS Magellan 8400 setting. By default, the scanner will scan fine the first time, but subsequent scans will fail. This is due to the default terminator from the scanner being CRLF when we expect only CR (the LF gets appended to the start of the next scan, causing it to not match in POS).
- First, as per other scanners, set the terminator byte to 0D (carriage Return).
- By default, the scanner uses CRLF as the terminator. We need to remove the LF using the configuration guide.