Oolio / Senor S-HF2D Scanner Manuals

If a S-HF2DV2 scanner is factory reset for troubleshooting, this will cause it to function differently than when it came out of the box, because Senor stages the scanners before sending them to us. From my testing, it will not read UPC-A barcodes correctly, which are common in Australia.

Firstly, factory reset using the following barcode:

Then, follow the 3 barcodes to configure the scanner correctly. (also found in the S-HF2DV2-STAGING.pdf below)


1: Add the scan delay between barcodes to avoid double scanning.


2: Enable support for large barcodes

3: Enable Leading Zero



Scan beep/volume settings can be found below:




The two barcodes I used for testing:

Generated from: UPC-A & EAN-13

After a factory reset, these barcodes should scan in like so:

EAN-13: 584498600374
UPC-A: 058449860037

 

After correct programming, these barcodes should scan like so:

EAN-13: 0584498600374
UPC-A: 0058449860037

 

Note: 
Some other scanners such as HANDHELD - Zebra Ll2208 will not read the UPC-A barcodes without correct config. 

 

S-HF2Dv1-UserManual

S-HF2Dv2-Current-UserManual

S-HF2Dv2-Oolio-UserManual